Reworked transmitter.
This commit is contained in:
187
doc/bbi_battery.txt
Normal file
187
doc/bbi_battery.txt
Normal file
@@ -0,0 +1,187 @@
|
||||
Battery information:
|
||||
Hardware version .....................: 62
|
||||
Software version .....................: 112
|
||||
Sub version ..........................: 45
|
||||
Part number ..........................: 05521
|
||||
Item number ..........................: 00011
|
||||
Manufacturing date ...................: 20.06.2012
|
||||
Location .............................: 65
|
||||
Cellpack item number .................: 03763
|
||||
Supervisor version ...................: 16
|
||||
Communication mode ...................: CAN
|
||||
BOM ..................................: SMC 6.2 or SMC 6.3r1
|
||||
Nominal voltage ......................: 48V
|
||||
PCB ..................................: no data
|
||||
|
||||
|
||||
Charger data
|
||||
------------
|
||||
Version ..............................: 45
|
||||
Mode .................................: Idle
|
||||
Charger manager status ...............: Charge done
|
||||
State flags ..........................: 0x4118
|
||||
Final voltage ........................: 54,210V
|
||||
Charge current .......................: 1,500A
|
||||
Voltage calibration ..................: 45,410V
|
||||
Current calibration ..................: 14,975A
|
||||
|
||||
Charging statistic
|
||||
------------------
|
||||
Charge time worst ....................: 488
|
||||
Charge time mean .....................: 11
|
||||
Charge cycles ........................: 77
|
||||
Full charge cycles ...................: 6
|
||||
Total charged energy .................: 12876Wh
|
||||
Total discharged energy ..............: 12436Wh
|
||||
Charges from level 10% ...............: 15
|
||||
Charges from level 20% ...............: 13
|
||||
Charges from level 30% ...............: 15
|
||||
Charges from level 40% ...............: 7
|
||||
Charges from level 50% ...............: 7
|
||||
Charges from level 60% ...............: 6
|
||||
Charges from level 70% ...............: 2
|
||||
Charges from level 80% ...............: 4
|
||||
Charges from level 90% ...............: 8
|
||||
Total # of charges ...................: 77
|
||||
|
||||
Readings
|
||||
--------
|
||||
Battery level ........................: 100,00%
|
||||
Voltage ..............................: 53,49V
|
||||
Relative voltage .....................: 110,83%
|
||||
Maximum relative voltage .............: 100,42%
|
||||
Minimum relative voltage .............: 100,00%
|
||||
Avg. relative voltage ................: 100,42%
|
||||
|
||||
Input voltage ........................: 25,80V
|
||||
Internal battery voltage .............: 53,40V
|
||||
Power voltage ........................: 0,00V
|
||||
Control voltage ......................: 12,04V
|
||||
Console voltage ......................: 5,43V
|
||||
12V voltage ..........................: 12,14V
|
||||
Accessory voltage reading ............: 0,00V
|
||||
|
||||
Cell monitor BOMID voltage ...........: 1099mV
|
||||
Cell monitor PackID voltage ..........: 2814mV
|
||||
Cell monitor 3.3V voltage ............: 3,23V
|
||||
Cell monitor 5V voltage ..............: 5,50V
|
||||
|
||||
Cellpack current .....................: 0,00A
|
||||
|
||||
Battery temp max .....................: 73C
|
||||
Battery temp min .....................: -17C
|
||||
|
||||
Power cycles .........................: 449
|
||||
Resets ...............................: 0
|
||||
Watchdog resets ......................: 0
|
||||
PowerOn resets .......................: 3
|
||||
RTC resync ...........................: 79
|
||||
|
||||
Deep sleep on inactivity count .......: 0 days
|
||||
Deep sleep on low SOC count ..........: 0 days
|
||||
Deep sleep on low voltage count ......: 0 days
|
||||
|
||||
Status leds ..........................: 0
|
||||
|
||||
Cellpack data
|
||||
-------------
|
||||
Cell organisation ....................: 13s5p
|
||||
Cell capacity ........................: 2,15Ah
|
||||
Max. cell drift w/o balancing ........: 0,02V
|
||||
Balancer active ......................: yes
|
||||
Cell data ............................: Cell [V] to GND [V] Calib [%]
|
||||
Cell # 1 ...........................: 4,068 4,068 0,810
|
||||
Cell # 2 ...........................: 4,082 8,150 0,330
|
||||
Cell # 3 ...........................: 4,082 12,232 0,240
|
||||
Cell # 4 ...........................: 4,085 16,317 0,540
|
||||
Cell # 5 ...........................: 4,098 20,414 -0,330
|
||||
Cell # 6 ...........................: 4,118 24,532 -0,150
|
||||
Cell # 7 ...........................: 4,102 28,633 0,060
|
||||
Cell # 8 ...........................: 4,107 32,740 -0,150
|
||||
Cell # 9 ...........................: 4,134 36,874 0,030
|
||||
Cell #10 ...........................: 4,165 41,039 -0,270
|
||||
Cell #11 ...........................: 4,133 45,173 0,120
|
||||
Cell #12 ...........................: 4,156 49,329 -0,450
|
||||
Cell #13 ...........................: 4,161 53,490 -0,060
|
||||
Temperature pack #1 ..................: 24C
|
||||
Temperature pack #2 ..................: 24C
|
||||
Temperature pack #3 ..................: 22C
|
||||
Temperature pack #4 ..................: 21C
|
||||
|
||||
Health
|
||||
------
|
||||
Low voltage alarm count ..............: 8960
|
||||
Cell dead short count ................: 0
|
||||
Cell partial short count .............: 0
|
||||
Cell voltage collapse count ..........: 0
|
||||
Control voltage shorts count .........: 0
|
||||
5V voltage shorts count ..............: 0
|
||||
RTC status ...........................: 0xA5 (in sync, Read ok, Osc ok, RTC detected)
|
||||
Status flags .........................: 0x0000 ()
|
||||
Permanent failure flag ...............: no
|
||||
|
||||
Configuration
|
||||
-------------
|
||||
Allow charging on bike ...............: yes
|
||||
Wake on power voltage ................: no
|
||||
Enable power voltage .................: no
|
||||
Enable control voltage ...............: yes
|
||||
Accessory mounted ....................: yes
|
||||
Accessory enabled ....................: no
|
||||
Accessory voltage ....................: 6,5V
|
||||
Accessory shutdown delay .............: 15s
|
||||
Taillamp intensity ...................: 0%
|
||||
Motor precharge time .................: 5s
|
||||
Power voltage shutdown delay .........: 2s
|
||||
System shutdown delay ................: 300s
|
||||
Enable internal battery voltage ......: yes
|
||||
Max. power voltage regen current .....: 10,00A
|
||||
Max. power voltage current ...........: 41,67A
|
||||
Cap sense SOC mode ...................: Inactive
|
||||
Deep sleep on inactivity delay .......: 60 days
|
||||
Deep sleep on low SOC delay ..........: 7 days
|
||||
Min. allowed gas gage temp. ..........: -30
|
||||
Max. allowed gas gage temp. ..........: 85
|
||||
Min. allowed pack temp. ..............: -30
|
||||
Max. allowed pack temp. ..............: 60
|
||||
Charger voltage calibration value ....: 45410,00
|
||||
Charger current calibration value ....: 65535,00
|
||||
Charger calibration value source .....: FF
|
||||
3V3 calibration value ................: 3,284
|
||||
Cap sense sensitivity ................: 7,00
|
||||
|
||||
Timestamps
|
||||
----------
|
||||
RTC time .............................: 399416969
|
||||
RTC time .............................: 14.02.2025 21:09:29
|
||||
Last valid battery timestamp .........: 399416134
|
||||
Last valid battery timestamp .........: 14.02.2025 20:55:34
|
||||
Last charge timestamp ................: 398852536
|
||||
Last charge timestamp ................: 08.02.2025 08:22:16
|
||||
|
||||
yet unassigned
|
||||
--------------
|
||||
LMD ..................................: 6,74Ah
|
||||
Estimated SOC ........................: 94%
|
||||
Shipmode .............................: yes
|
||||
Config type ..........................: 3
|
||||
Diag .................................: 0
|
||||
LMD adapt ............................: 5
|
||||
RTC control ..........................: 204
|
||||
ILMD .................................: 10,42Ah
|
||||
Gasgage DMFSD ........................: 242
|
||||
Gasgage SOC ..........................: 100%
|
||||
Gasgage AI ...........................: 0,08A
|
||||
Gasgage LMD ..........................: 6,74Ah
|
||||
Gasgage status flags .................: 14
|
||||
Gasgage voltage ......................: 52,96V
|
||||
Gasgage temperature ..................: 31,75C
|
||||
Gasgage voltage divider ..............: 15,40
|
||||
Gasgage jitter calibration ...........: 0
|
||||
NAC ..................................: 3141
|
||||
ProtectMode ..........................: 64
|
||||
ProtectControl .......................: 0
|
||||
Test flags ...........................: 0007
|
||||
Battery test button sensitivity ......: 32825
|
||||
Battery test button sensitivity reference : 32569
|
||||
|
||||
Reference in New Issue